Fire Alarms

XTREME XD20 Smoke Detector

TESTING EQUIPMENT

In order to maintain the smooth operation of the device, it must undergo regular maintenance and be checked regularly.

SELECTION SYSTEM

To ensure the highest level of protection, it...

TESTING EQUIPMENT

In order to maintain the smooth operation of the device, it must undergo regular maintenance and be checked regularly.

SELECTION SYSTEM

To ensure the highest level of protection, it is recommended to install the device in all areas and on every level of a residential building (and wherever there is equipment or installation that could...

See full description See full description
What if it breaks?

You have at least a 2-year warranty. Contact us by phone and we will immediately take care of the repair, replacement or refund of your money, completely free of charge.

What if I change my mind?

No problem, as long as it's within 14 days. We'll come pick it up or you can choose the Skroutz Point that suits you, completely free for up to 2 times per year, and we'll refund your money. Get Skroutz Plus to enjoy unlimited free returns.

Description

Description

TESTING EQUIPMENT

In order to maintain the smooth operation of the device, it must undergo regular maintenance and be checked regularly.

SELECTION SYSTEM

To ensure the highest level of protection, it is recommended to install the device in all areas and on every level of a residential building (and wherever there is equipment or installation that could potentially be a source of fire, as well as in other rooms).

USAGE PERIOD

The average lifespan of the device (electronic sensor) is approximately 5 years. This strictly depends on the environmental conditions in which the tool operates, the manufacturing date, and the number of activations (alarm, etc.). Regular replacement of worn-out devices with new models is recommended.

Safety Instructions

  • To minimize the risk of fire, specialized professionals should regularly (at least once every six months) check the heating system, ventilation system, chimneys, and exhausts from moving fuel appliances.
  • All heating devices must always be installed in accordance with the manufacturer's instructions and comply with local building codes.
  • All devices must be installed and checked by specialists after installation.
  • Regularly inspect the fuel supply or exhaust pipe for any leaks, cracks, rust, etc.
  • Always read the manual for the alarm devices used in the installation.

START-UP ALARM

Upon activation of the alarm:

  • MANDATORILY leave the room where the smoke alarm has been triggered.
  • Contact the Fire Department or the Police.
  • If you notice any symptoms of poisoning (e.g., headache), contact your doctor immediately.
  • In case of a false alarm, check for proper installation and the choice of installation location.

FEATURES

  • High-quality photoelectric sensor.
  • Powered by a 230V 50Hz network, 9V 6LR61 battery backup.
  • Sound alarm signaling and visual signaling device.
  • Built-in electronic unit for monitoring and verifying the correct operation of the device.
  • Signaling for the need to replace the battery (BEEP periodically repeated at regular intervals - approximately every 40 seconds).
  • Energy-saving mode.
  • High efficiency.

SPECIFICATIONS

  • Power supply: battery/emergency 230V AC 6LR61 9V (battery included).
  • Sensor type: photoelectric.
  • Standby power consumption: > 10uA.
  • Alarm power consumption: > 10mA.
  • Volume: > 80 dB.
  • Allowed temperature range: 50°C - 100°C.
  • Maximum humidity: 10% - 90% RH.

Manufacturer

See full description

Specifications

Specifications

Dimensions

Type
Smoke Detector
Thread
No
Autonomous
No

Smart Features

Smart Ecosystem
-

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description & Specifications

TESTING EQUIPMENT

In order to maintain the smooth operation of the device, it must undergo regular maintenance and be checked regularly.

SELECTION SYSTEM

To ensure the highest level of protection, it is recommended to install the device in all areas and on every level of a residential building (and wherever there is equipment or installation that could potentially be a source of fire, as well as in other rooms).

USAGE PERIOD

The average lifespan of the device (electronic sensor) is approximately 5 years. This strictly depends on the environmental conditions in which the tool operates, the manufacturing date, and the number of activations (alarm, etc.). Regular replacement of worn-out devices with new models is recommended.

Safety Instructions

  • To minimize the risk of fire, specialized professionals should regularly (at least once every six months) check the heating system, ventilation system, chimneys, and exhausts from moving fuel appliances.
  • All heating devices must always be installed in accordance with the manufacturer's instructions and comply with local building codes.
  • All devices must be installed and checked by specialists after installation.
  • Regularly inspect the fuel supply or exhaust pipe for any leaks, cracks, rust, etc.
  • Always read the manual for the alarm devices used in the installation.

START-UP ALARM

Upon activation of the alarm:

  • MANDATORILY leave the room where the smoke alarm has been triggered.
  • Contact the Fire Department or the Police.
  • If you notice any symptoms of poisoning (e.g., headache), contact your doctor immediately.
  • In case of a false alarm, check for proper installation and the choice of installation location.

FEATURES

  • High-quality photoelectric sensor.
  • Powered by a 230V 50Hz network, 9V 6LR61 battery backup.
  • Sound alarm signaling and visual signaling device.
  • Built-in electronic unit for monitoring and verifying the correct operation of the device.
  • Signaling for the need to replace the battery (BEEP periodically repeated at regular intervals - approximately every 40 seconds).
  • Energy-saving mode.
  • High efficiency.

SPECIFICATIONS

  • Power supply: battery/emergency 230V AC 6LR61 9V (battery included).
  • Sensor type: photoelectric.
  • Standby power consumption: > 10uA.
  • Alarm power consumption: > 10mA.
  • Volume: > 80 dB.
  • Allowed temperature range: 50°C - 100°C.
  • Maximum humidity: 10% - 90% RH.

Manufacturer

Dimensions

Type
Smoke Detector
Thread
No
Autonomous
No

Smart Features

Smart Ecosystem
-

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

14,55 €
2,50 € to a Skroutz Point
or   3,50 €   shipping cost
5€ coupon from the shop Tsimhub until 12/07!
5€ coupon from the shop Tsimhub until 12/07!
See more