Heat Pumps

Aux Achp-h08/4r3ha Heat Pump 8kW Split Code: ACHP-H08/4R3HA

Split Type Heat Pumps

Discover the new series of AI – Therma heat pumps by AUX with the ability to connect to radiators, underfloor heating, fan coil units, and simultaneous production of domestic hot...

Split Type Heat Pumps

Discover the new series of AI – Therma heat pumps by AUX with the ability to connect to radiators, underfloor heating, fan coil units, and simultaneous production of domestic hot water.

Specifications

  • Indoor Unit Model: ACHP-H08/4R3HA-I
  • Outdoor Unit Model: ACHP-H08/4R3HA-I
  • Output: 8kW
  • Power Consumption: Indoor (V~,Hz,Ph) 380-415/3/50,...
See full description See full description

3859 97
3,86€ cashback in Coins 3,86€ cashback in Coins
Delivery Wed, 05 Aug - Fri, 07 Aug
31,50 €  
Delivery to your floor available
Do you want it with Free shipping?
From Klimamall
Μεταμόρφωση, Αττικής
In-store pickup available
See Central Heating on the page of Klimamall
What if it breaks?

You're covered by the statutory 2-year warranty. Contact us and we'll handle the entire process with the store, ensuring your issue is resolved with prompt support through a repair, replacement, or refund.

What if I change my mind?

No problem, as long as it's within 14 days. We'll come and pick it up (completely free of charge if you have Skroutz Plus) and refund your money.

Is delivery to a floor free?

Yes, we will carry it up to the floor for you, without any restrictions.

You can select additional services after adding the product to the cart.

Description

Description

Split Type Heat Pumps

Discover the new series of AI – Therma heat pumps by AUX with the ability to connect to radiators, underfloor heating, fan coil units, and simultaneous production of domestic hot water.

Specifications

  • Indoor Unit Model: ACHP-H08/4R3HA-I
  • Outdoor Unit Model: ACHP-H08/4R3HA-I
  • Output: 8kW
  • Power Consumption: Indoor (V~,Hz,Ph) 380-415/3/50, Outdoor (V~,Hz,Ph) 220-240/1/50
  • Heating (7°C outdoor temperature): Water outlet temperature 35°C, Output (kW) 8.40, Consumption (kW) 1.62, COP 5.20
  • Cooling (35°C outdoor temperature): Water outlet temperature 18°C, Output (kW) 8.45, Consumption (kW) 1.67, EER 5.06
  • Compressor: DC Inverter, Twin rotary GMCC type
  • Dimensions and Weight: Indoor Unit (mm) 420×270×790, Outdoor Unit (mm) 970x395x805, Indoor Net (kg) 39, Outdoor Net (kg) 65
  • Refrigerant: R32, Quantity 1.45kg
  • Operating Range of Outdoor Temperature: Cooling (°C) -5 ~ 52, Heating (°C) -25 ~ 35

Manufacturer

See full description

Specifications

Specifications

Product Number
ACHP-H08/4R3HA

Technical Specifications

Rated Thermal Power (7ºC - 35ºC)
8 kW
Maximum Water Temperature
65 °C
Heating Type
Air to Water
System Type
Split
Cooling
Yes
Domestic Hot Water
No Domestic Water Supply
Power Source
Single Phase

Energy Class

Energy Class (35ºC)
-
Energy Class (55ºC)
-
COP (7ºC - 35ºC)
-
EER (7ºC - 35ºC)
-
Indoor Unit Noise Level
-
Outdoor Unit Noise Level
-

Outdoor Dimensions

Length
-
Height
-
Length
-

Indoor Dimensions

Length
-
Height
-
Length
-

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description & Specifications

Split Type Heat Pumps

Discover the new series of AI – Therma heat pumps by AUX with the ability to connect to radiators, underfloor heating, fan coil units, and simultaneous production of domestic hot water.

Specifications

  • Indoor Unit Model: ACHP-H08/4R3HA-I
  • Outdoor Unit Model: ACHP-H08/4R3HA-I
  • Output: 8kW
  • Power Consumption: Indoor (V~,Hz,Ph) 380-415/3/50, Outdoor (V~,Hz,Ph) 220-240/1/50
  • Heating (7°C outdoor temperature): Water outlet temperature 35°C, Output (kW) 8.40, Consumption (kW) 1.62, COP 5.20
  • Cooling (35°C outdoor temperature): Water outlet temperature 18°C, Output (kW) 8.45, Consumption (kW) 1.67, EER 5.06
  • Compressor: DC Inverter, Twin rotary GMCC type
  • Dimensions and Weight: Indoor Unit (mm) 420×270×790, Outdoor Unit (mm) 970x395x805, Indoor Net (kg) 39, Outdoor Net (kg) 65
  • Refrigerant: R32, Quantity 1.45kg
  • Operating Range of Outdoor Temperature: Cooling (°C) -5 ~ 52, Heating (°C) -25 ~ 35

Manufacturer

Product Number
ACHP-H08/4R3HA

Technical Specifications

Rated Thermal Power (7ºC - 35ºC)
8 kW
Maximum Water Temperature
65 °C
Heating Type
Air to Water
System Type
Split
Cooling
Yes
Domestic Hot Water
No Domestic Water Supply
Power Source
Single Phase

Energy Class

Energy Class (35ºC)
-
Energy Class (55ºC)
-
COP (7ºC - 35ºC)
-
EER (7ºC - 35ºC)
-
Indoor Unit Noise Level
-
Outdoor Unit Noise Level
-

Outdoor Dimensions

Length
-
Height
-
Length
-

Indoor Dimensions

Length
-
Height
-
Length
-

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

3.859,97 €
31,50 €  
Delivery to your floor available