Water Quality Meters

Hanna Ammonia Measurement Photometer

Medium-range ammonia meter HI715 bridges the gap between simple chemical test kits and professional instruments.

See full description
88 04
89 Coins 89 Coins
Delivery by Tue, 07 Jul
2,50 € to a Skroutz Point
Do you want it with Free shipping?
From Biopureshop 3.3 (4)
Αθήνα, Αττικής
1 piece
See Environmental Measurements on the page of Biopureshop
What if it breaks?

You have at least a 2-year warranty. Contact us by phone and we will immediately take care of the repair, replacement or refund of your money, completely free of charge.

What if I change my mind?

No problem, as long as it's within 14 days. We'll come pick it up or you can choose the Skroutz Point that suits you, completely free for up to 2 times per year, and we'll refund your money. Get Skroutz Plus to enjoy unlimited free returns.

Description

Description

The HI715 medium range ammonia meter bridges the gap between simple chemical test kits and professional instruments. Chemical test kits have limited accuracy and resolution, as they rely on the human eye to distinguish color differences. 

Professional instruments incorporate a light source such as an LED or tungsten lamp with a filter and a light detector for precise determination of absorption and ion concentration. Professional instruments provide higher resolution and accuracy, but can be expensive. The HI715 medium range ammonia meter from Hanna uses a fixed wavelength LED and a pyrite photodiode detector for the accuracy of professional instruments at an affordable price of a chemical test kit.

Technical Specifications

  • Range: 0.00 to 9.99 ppm NH3-N
  • Resolution: 0.01 ppm
  • Accuracy at 25°C / 77°F: 0.05 ppm 5% of reading
  • Light Source: LED lamp at 470nm
  • Light Detector: Pyrite photocell
  • Method: Adaptation of ASTM manual for water and environmental technology D-1426-92, Nessler method. The reaction between ammonia and reagents causes a yellow coloration in the sample.
  • Environment: 0 to 50°C (32 to 122°F). Maximum 95% RH without condensation
  • Battery Type: (1) 1.5V AAA
  • Auto Power Off: After 10 minutes of non-use
  • Dimensions: 81.5mm x 61mm x 37.5mm
  • Weight: 64 gr

"Included in the package"

  • The medium range ammonia meter HI715
  • 2 sample cells with caps
  • Ammonia reagent starter kit for 25 tests (1 bottle HI715A-0 and 1 bottle HI715B-0)
  • Syringe with tip
  • Battery
  • Instructions

Manufacturer

See full description

Specifications

Specifications

Dimensions

Digital
Yes
Calibration Capability
No
ATC
No
Photometer Type
Ammonia

Measurement Capability

TDS
No
EC
No
pH
No
Temperature
No
ORP
No
Salinity
No
Hardness
-

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description & Specifications

The HI715 medium range ammonia meter bridges the gap between simple chemical test kits and professional instruments. Chemical test kits have limited accuracy and resolution, as they rely on the human eye to distinguish color differences. 

Professional instruments incorporate a light source such as an LED or tungsten lamp with a filter and a light detector for precise determination of absorption and ion concentration. Professional instruments provide higher resolution and accuracy, but can be expensive. The HI715 medium range ammonia meter from Hanna uses a fixed wavelength LED and a pyrite photodiode detector for the accuracy of professional instruments at an affordable price of a chemical test kit.

Technical Specifications

  • Range: 0.00 to 9.99 ppm NH3-N
  • Resolution: 0.01 ppm
  • Accuracy at 25°C / 77°F: 0.05 ppm 5% of reading
  • Light Source: LED lamp at 470nm
  • Light Detector: Pyrite photocell
  • Method: Adaptation of ASTM manual for water and environmental technology D-1426-92, Nessler method. The reaction between ammonia and reagents causes a yellow coloration in the sample.
  • Environment: 0 to 50°C (32 to 122°F). Maximum 95% RH without condensation
  • Battery Type: (1) 1.5V AAA
  • Auto Power Off: After 10 minutes of non-use
  • Dimensions: 81.5mm x 61mm x 37.5mm
  • Weight: 64 gr

"Included in the package"

  • The medium range ammonia meter HI715
  • 2 sample cells with caps
  • Ammonia reagent starter kit for 25 tests (1 bottle HI715A-0 and 1 bottle HI715B-0)
  • Syringe with tip
  • Battery
  • Instructions

Manufacturer

Dimensions

Digital
Yes
Calibration Capability
No
ATC
No
Photometer Type
Ammonia

Measurement Capability

TDS
No
EC
No
pH
No
Temperature
No
ORP
No
Salinity
No
Hardness
-

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

88,04 €
2,50 € to a Skroutz Point
Kέρδισε 50€ κουπόνι
Kέρδισε 50€ κουπόνι
Δες πώς εδώ