Misc Industrial Building Equipment

Hager Coil Industrial Type Voltage Drop Coil 230VAC MZ206

Release of under-voltage 230V AC (MZ206)

  • Number of poles: 1
  • Rated insulation voltage Ui: 4000 V
  • Rated frequency: 50/60 Hz
  • Tightening torque: 1.2 Nm
  • Number of wires - soldered: 6mm²
  • Number of wires -...

Release of under-voltage 230V AC (MZ206)

  • Number of poles: 1
  • Rated insulation voltage Ui: 4000 V
  • Rated frequency: 50/60 Hz
  • Tightening torque: 1.2 Nm
  • Number of wires - soldered: 6mm²
  • Number of wires - solid: 10mm²
  • Total power loss for rated current: 2 W
  • Maximum power consumed: 3.5 VA
  • Operating temperature: -25 to 60 °C
  • Storage temperature: -40 to 80 °C
  • Width...
See full description See full description
31 50
62 bonus Coins 62 bonus Coins
Delivery by Fri, 14 Aug
2,50 € to a Skroutz Point
Do you want it with Free shipping?
From Meidanis 4.8 (56)
Καλλιθέα, Αττικής
1 piece
See Industrial Materials on the page of Meidanis
What if it breaks?

You're covered by the statutory 2-year warranty. Contact us and we'll handle the entire process with the store, ensuring your issue is resolved with prompt support through a repair, replacement, or refund.

What if I change my mind?

No problem, as long as it's within 14 days. We'll come pick it up or you can choose the Skroutz Point that suits you, completely free for up to 2 times per year, and we'll refund your money. Get Skroutz Plus to enjoy unlimited free returns.

Description

Description

Release of under-voltage 230V AC (MZ206)

  • Number of poles: 1
  • Rated insulation voltage Ui: 4000 V
  • Rated frequency: 50/60 Hz
  • Tightening torque: 1.2 Nm
  • Number of wires - soldered: 6mm²
  • Number of wires - solid: 10mm²
  • Total power loss for rated current: 2 W
  • Maximum power consumed: 3.5 VA
  • Operating temperature: -25 to 60 °C
  • Storage temperature: -40 to 80 °C
  • Width of installed product: 17.5 mm
  • Depth of installed product: 68 mm
  • Response time during opening: 200 ms
  • Activation of the circuit breaker when the network voltage drops.
  • Activation range: 70% Un: standby. Only after the application of the network voltage can the circuit breaker be activated.

Manufacturer

See full description

Specifications

Specifications

Type
Coil

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description & Specifications

Release of under-voltage 230V AC (MZ206)

  • Number of poles: 1
  • Rated insulation voltage Ui: 4000 V
  • Rated frequency: 50/60 Hz
  • Tightening torque: 1.2 Nm
  • Number of wires - soldered: 6mm²
  • Number of wires - solid: 10mm²
  • Total power loss for rated current: 2 W
  • Maximum power consumed: 3.5 VA
  • Operating temperature: -25 to 60 °C
  • Storage temperature: -40 to 80 °C
  • Width of installed product: 17.5 mm
  • Depth of installed product: 68 mm
  • Response time during opening: 200 ms
  • Activation of the circuit breaker when the network voltage drops.
  • Activation range: 70% Un: standby. Only after the application of the network voltage can the circuit breaker be activated.

Manufacturer

Type
Coil

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

31,50 €
2,50 € to a Skroutz Point