Unimac 41642 Air Tool Part

The dehydration is equipped with an alarm function. The alarm is activated when the valve opens too many consecutive times (>100) without pause. This could be due to debris particles (rust) blocking...

The dehydration is equipped with an alarm function. The alarm is activated when the valve opens too many consecutive times (>100) without pause. This could be due to debris particles (rust) blocking the valve, the outlet, the filter, or a sensor malfunction indicating the need for maintenance.

The dehydration switches to alarm mode after 100 consecutive...

See full description See full description
This product is temporarily unavailable at Skroutz Last updated: 19 days ago

Description

Description

The dehydration is equipped with an alarm function. The alarm is activated when the valve opens too many consecutive times (>100) without pause. This could be due to debris particles (rust) blocking the valve, the outlet, the filter, or a sensor malfunction indicating the need for maintenance.

The dehydration switches to alarm mode after 100 consecutive "open and close" cycles. In alarm mode, the dehydration will operate on a timer for 2 minutes, draining for 5 seconds every minute. After these 2 minutes, the drainage conduit will check if it is possible to return to normal operation.

  • Up to 10 m³/min or up to 600 m³ per hour.
  • Maximum operating pressure 16 bar.
  • Connection thread 1/2''.
  • Outlet fitting 1/4'' to 10mm.
  • Low height 74 mm.
  • Manual control operation -TEST.

Manufacturer

See full description

Specifications

Specifications

Product Type
Miscellaneous Parrts
Pieces
1 pcs

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description & Specifications

The dehydration is equipped with an alarm function. The alarm is activated when the valve opens too many consecutive times (>100) without pause. This could be due to debris particles (rust) blocking the valve, the outlet, the filter, or a sensor malfunction indicating the need for maintenance.

The dehydration switches to alarm mode after 100 consecutive "open and close" cycles. In alarm mode, the dehydration will operate on a timer for 2 minutes, draining for 5 seconds every minute. After these 2 minutes, the drainage conduit will check if it is possible to return to normal operation.

  • Up to 10 m³/min or up to 600 m³ per hour.
  • Maximum operating pressure 16 bar.
  • Connection thread 1/2''.
  • Outlet fitting 1/4'' to 10mm.
  • Low height 74 mm.
  • Manual control operation -TEST.