Heat Pumps

AUX Three-Phase Heat Pump 16.10kW 65°C Monoblock Code: ACHP-H16/5R3HA-ME

Monoblock Heat Pumps

The A.I. Therma heat pumps use the latest technology to offer maximum energy savings in your space, in the simplest way. Their special design combined with the latest generation...

Monoblock Heat Pumps

The A.I. Therma heat pumps use the latest technology to offer maximum energy savings in your space, in the simplest way. Their special design combined with the latest generation compressors provide the system with increased reliability and high performance.

  • Cooling / Heating Performance
  • Heating Performance (medium zone)
    • Water outlet...
See full description See full description
5188 00 €
5,19€ cashback in Coins 5,19€ cashback in Coins
Delivery Wed, 14 Oct - Fri, 16 Oct
31,50 €  
Delivery to your floor available
Do you want it with Free shipping?
From Energylife
Πειραιάς, Αττικής
5+ pieces
See Central Heating on the page of Energylife
What if it breaks?

You're covered by the statutory 2-year warranty. Contact us and we'll handle the entire process with the store, ensuring your issue is resolved with prompt support through a repair, replacement, or refund.

What if I change my mind?

No problem, as long as it's within 14 days. We'll come and pick it up (completely free of charge if you have Skroutz Plus) and refund your money.

Is delivery to a floor free?

Yes, we will carry it up to the floor for you, without any restrictions.

Description

Description

Monoblock Heat Pumps

The A.I. Therma heat pumps use the latest technology to offer maximum energy savings in your space, in the simplest way. Their special design combined with the latest generation compressors provide the system with increased reliability and high performance.

  • Cooling / Heating Performance
  • Heating Performance (medium zone)
    • Water outlet temperature 35°C: Performance (kW) 16.10, Consumption (kW) 3.57, COP 4.51
    • Water outlet temperature 55°C: Performance (kW) 16.10, Consumption (kW) 5.53, COP 2.91
  • Cooling Performance
    • Water outlet temperature 18°C: Performance (kW) 15.00, Consumption (kW) 4.41, EER 3.40
    • Water outlet temperature 7°C: Performance (kW) 14.00, Consumption (kW) 5.70, EER 2.46
  • SCOP (medium zone)
    • Water outlet 35°C/55°C: 4.63/3.43
  • Seasonal Energy Class Heating (medium zone)
    • Water outlet 35°C/55°C: A+++ / A++
  • Electrical Specifications
    • Internal Power Supply (V~,Hz,Ph): 380-415/3/50
    • MOP (Maximum Overcurrent Protection Amps (A)): 14
  • Installation & Operation Specifications
    • Pipe Dimensions: inch G1"BSP
    • Expansion Tank: lt 8
    • Auxiliary Electric Resistance: kW 9
    • Refrigerant / Quantity / Additional Refrigerant after 15m: R32 / 1.70 Kg
    • Noise Level / Sound Power: dB(A) 31 / 65
    • Power/Communication Wiring: 3x6 / 2x1 (Shield)
    • Weight: Net/Gross kg 141 / 153
    • Unit Dimensions (LxWxH) mm: 1385x520x933
    • Packaging mm: 1465x550x1095
    • Temperature Adjustment Range
      • Cooling °C: 5 - 25
      • Heating °C: 12 - 65
      • DHW (tank) °C: 30 - 60
    • Operating Range of External Temperature
      • Cooling °C: -5 - 43
      • Heating °C: -25 - 35
      • DHW °C: -25 - 43

Manufacturer

See full description

Specifications

Specifications

Product Number
ACHP-H16/5R3HA-ME

Technical Specifications

Rated Thermal Power (7ºC - 35ºC)
16.1 kW
Maximum Water Temperature
65 °C
Heating Type
Air to Water
System Type
Monoblock
Cooling
Yes
Domestic Hot Water
Optional Domestic Water Supply
Power Source
Three-Phase
Type of Refrigerant Fluid
R32

Energy Class

Energy Class (35ºC)
-
Energy Class (55ºC)
-
COP (7ºC - 35ºC)
4.51
EER (7ºC - 35ºC)
-
Outdoor Unit Noise Level
-

Outdoor Dimensions

Length
1385 mm
Height
933 mm
Length
520 mm

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Reviews (1)

Reviews

  1. 1
  2. 4 stars
    0
  3. 3 stars
    0
  4. 2 stars
    0
  5. 1 star
    0
Review this product

Reviews photos

Reviews photos
Reviews photos
Reviews photos

Reviews by our members

  • SAKIS_LEPIDAS
    5
    15 out of 15 members found this review helpful

    I used it for an entire winter, from early Oct 24 to mid May 25, in a city in Northern Greece. 2500 kW for the whole period with the house temperature at 22-23+. Low supply temperatures. In a few cases 45. Mostly 33 to 40 degrees Celsius. (Roughly, roughly €500 in electricity) The price of the heat pump is particularly competitive compared to other more well-known brands; I haven’t needed the service or support yet, so I don’t have an opinion. Anyone who has a question and I can help, I’ll be happy to. It has an app for remote control, kW consumption measurement, and so on. Recently I also found the way to do compensation. So after using it and in the second year I’ll see whether consumption will really drop further. (unfortunately the technician didn’t suggest it to me from the start and I learned it by chance). - Year 2025-2026. After a slightly better and more rational use, smaller supply fluctuations from 31 to 37 (using compensation), better humidity levels with the use of a second dehumidifier, I have dropped a little below 1800 kW. No, we did not get cold. The house’s average temperature went up, humidity as well as the pump’s kW went down (-700 kW). The measurement was done with smart meters and is not a rough estimate. Maybe it was balanced out as final consumption with that of the 2nd dehumidifier (so to speak), but okay. As a result of home comfort and hygiene: A+++. Worth the investment. Also, the company’s app improved after a few minor problems I had encountered in the first year.

    Translated from Greek ·
    Did you find this review helpful?
  • I used it for an entire winter, from early Oct 24 to mid May 25, in a city in Northern Greece. 2500 kW for the whole period with the house temperature at 22-23+. Low supply temperatures. In a few cases 45. Mostly 33 to 40 degrees Celsius. (Roughly, roughly €500 in electricity) The price of the heat pump is particularly competitive compared to other more well-known brands; I haven’t needed the service or support yet, so I don’t have an opinion. Anyone who has a question and I can help, I’ll be happy to. It has an app for remote control, kW consumption measurement, and so on. Recently I also found the way to do compensation. So after using it and in the second year I’ll see whether consumption will really drop further. (unfortunately the technician didn’t suggest it to me from the start and I learned it by chance). - Year 2025-2026. After a slightly better and more rational use, smaller supply fluctuations from 31 to 37 (using compensation), better humidity levels with the use of a second dehumidifier, I have dropped a little below 1800 kW. No, we did not get cold. The house’s average temperature went up, humidity as well as the pump’s kW went down (-700 kW). The measurement was done with smart meters and is not a rough estimate. Maybe it was balanced out as final consumption with that of the 2nd dehumidifier (so to speak), but okay. As a result of home comfort and hygiene: A+++. Worth the investment. Also, the company’s app improved after a few minor problems I had encountered in the first year.

    Translated from Greek ·
    15
  • See all
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description & Specifications

Monoblock Heat Pumps

The A.I. Therma heat pumps use the latest technology to offer maximum energy savings in your space, in the simplest way. Their special design combined with the latest generation compressors provide the system with increased reliability and high performance.

  • Cooling / Heating Performance
  • Heating Performance (medium zone)
    • Water outlet temperature 35°C: Performance (kW) 16.10, Consumption (kW) 3.57, COP 4.51
    • Water outlet temperature 55°C: Performance (kW) 16.10, Consumption (kW) 5.53, COP 2.91
  • Cooling Performance
    • Water outlet temperature 18°C: Performance (kW) 15.00, Consumption (kW) 4.41, EER 3.40
    • Water outlet temperature 7°C: Performance (kW) 14.00, Consumption (kW) 5.70, EER 2.46
  • SCOP (medium zone)
    • Water outlet 35°C/55°C: 4.63/3.43
  • Seasonal Energy Class Heating (medium zone)
    • Water outlet 35°C/55°C: A+++ / A++
  • Electrical Specifications
    • Internal Power Supply (V~,Hz,Ph): 380-415/3/50
    • MOP (Maximum Overcurrent Protection Amps (A)): 14
  • Installation & Operation Specifications
    • Pipe Dimensions: inch G1"BSP
    • Expansion Tank: lt 8
    • Auxiliary Electric Resistance: kW 9
    • Refrigerant / Quantity / Additional Refrigerant after 15m: R32 / 1.70 Kg
    • Noise Level / Sound Power: dB(A) 31 / 65
    • Power/Communication Wiring: 3x6 / 2x1 (Shield)
    • Weight: Net/Gross kg 141 / 153
    • Unit Dimensions (LxWxH) mm: 1385x520x933
    • Packaging mm: 1465x550x1095
    • Temperature Adjustment Range
      • Cooling °C: 5 - 25
      • Heating °C: 12 - 65
      • DHW (tank) °C: 30 - 60
    • Operating Range of External Temperature
      • Cooling °C: -5 - 43
      • Heating °C: -25 - 35
      • DHW °C: -25 - 43

Manufacturer

Product Number
ACHP-H16/5R3HA-ME

Technical Specifications

Rated Thermal Power (7ºC - 35ºC)
16.1 kW
Maximum Water Temperature
65 °C
Heating Type
Air to Water
System Type
Monoblock
Cooling
Yes
Domestic Hot Water
Optional Domestic Water Supply
Power Source
Three-Phase
Type of Refrigerant Fluid
R32

Energy Class

Energy Class (35ºC)
-
Energy Class (55ºC)
-
COP (7ºC - 35ºC)
4.51
EER (7ºC - 35ºC)
-
Outdoor Unit Noise Level
-

Outdoor Dimensions

Length
1385 mm
Height
933 mm
Length
520 mm

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

Reviews (1)

  1. 1
  2. 4 stars
    0
  3. 3 stars
    0
  4. 2 stars
    0
  5. 1 star
    0
Review this product

Reviews photos

Reviews photos
Reviews photos
Reviews photos

Reviews by our members

  • SAKIS_LEPIDAS
    5
    15 out of 15 members found this review helpful

    I used it for an entire winter, from early Oct 24 to mid May 25, in a city in Northern Greece. 2500 kW for the whole period with the house temperature at 22-23+. Low supply temperatures. In a few cases 45. Mostly 33 to 40 degrees Celsius. (Roughly, roughly €500 in electricity) The price of the heat pump is particularly competitive compared to other more well-known brands; I haven’t needed the service or support yet, so I don’t have an opinion. Anyone who has a question and I can help, I’ll be happy to. It has an app for remote control, kW consumption measurement, and so on. Recently I also found the way to do compensation. So after using it and in the second year I’ll see whether consumption will really drop further. (unfortunately the technician didn’t suggest it to me from the start and I learned it by chance). - Year 2025-2026. After a slightly better and more rational use, smaller supply fluctuations from 31 to 37 (using compensation), better humidity levels with the use of a second dehumidifier, I have dropped a little below 1800 kW. No, we did not get cold. The house’s average temperature went up, humidity as well as the pump’s kW went down (-700 kW). The measurement was done with smart meters and is not a rough estimate. Maybe it was balanced out as final consumption with that of the 2nd dehumidifier (so to speak), but okay. As a result of home comfort and hygiene: A+++. Worth the investment. Also, the company’s app improved after a few minor problems I had encountered in the first year.

    Translated from Greek ·
    Did you find this review helpful?
  • I used it for an entire winter, from early Oct 24 to mid May 25, in a city in Northern Greece. 2500 kW for the whole period with the house temperature at 22-23+. Low supply temperatures. In a few cases 45. Mostly 33 to 40 degrees Celsius. (Roughly, roughly €500 in electricity) The price of the heat pump is particularly competitive compared to other more well-known brands; I haven’t needed the service or support yet, so I don’t have an opinion. Anyone who has a question and I can help, I’ll be happy to. It has an app for remote control, kW consumption measurement, and so on. Recently I also found the way to do compensation. So after using it and in the second year I’ll see whether consumption will really drop further. (unfortunately the technician didn’t suggest it to me from the start and I learned it by chance). - Year 2025-2026. After a slightly better and more rational use, smaller supply fluctuations from 31 to 37 (using compensation), better humidity levels with the use of a second dehumidifier, I have dropped a little below 1800 kW. No, we did not get cold. The house’s average temperature went up, humidity as well as the pump’s kW went down (-700 kW). The measurement was done with smart meters and is not a rough estimate. Maybe it was balanced out as final consumption with that of the 2nd dehumidifier (so to speak), but okay. As a result of home comfort and hygiene: A+++. Worth the investment. Also, the company’s app improved after a few minor problems I had encountered in the first year.

    Translated from Greek ·
    15
  • See all
5.188,00 €
31,50 €  