Technical Specifications LT2-K:
- Nominal operating current: 0.10 to 93A
- Nominal operating voltage: up to 690V AC; 50/60Hz
- Insulation voltage: >690V
- Impulse voltage withstand: 6000V
- Mechanical wear resistance (number of cycles): ≥10000000
- Electrical wear resistance (number of cycles): ≥1000000
- Ambient temperature: -10° to 65ºC
- Maximum altitude: up to 2000m
Advantages:
- Indicator for protection activation
- Option to select protection reset method
- Ability to adjust the operating range
- Allows operation at higher frequency
- High reliability of current parameters
- Increases efficiency and extends lifespan
Functions:
- For protecting electric motors from overload or overheating
- To prevent motor operation under unusual temperature conditions
Applications:
- Industry
- Construction
Mounting: On the terminal contacts of the protector and additionally secured to the frame via a nail
Standards: EN60947-1; EN60947-4-1; LVD; EMC