Heat Pumps

AUX Three-Phase Heat Pump 12kW 60°C Monoblock Code: ACHP-H12/5R3HA-R32

The heat pump ACHP-H12/5R3HA-M from AUX is a device that extracts energy from the outside and transfers it indoors, providing heating and cooling. It heats the space by extracting heat from the...

The heat pump ACHP-H12/5R3HA-M from AUX is a device that extracts energy from the outside and transfers it indoors, providing heating and cooling. It heats the space by extracting heat from the environment and channeling it indoors, while for cooling, it extracts heat from the interior and expels it into the environment.

It can be connected to a single-phase...

See full description See full description

6200 00
6,20€ cashback in Coins 6,20€ cashback in Coins
Delivery up to 10 days
55,30 €  
Delivery to your floor available
Do you want it with 20,30 € shipping?
From KLIMATISMOS KARAGIANNIS
Γλυφάδα, Αττικής
1 piece
See Central Heating on the page of KLIMATISMOS KARAGIANNIS
What if it breaks?

You're covered by the statutory 2-year warranty. Contact us and we'll handle the entire process with the store, ensuring your issue is resolved with prompt support through a repair, replacement, or refund.

What if I change my mind?

No problem, as long as it's within 14 days. We'll come and pick it up (completely free of charge if you have Skroutz Plus) and refund your money.

Is delivery to a floor free?

Yes, we will carry it up to the floor for you, without any restrictions.

Description

Description

The heat pump ACHP-H12/5R3HA-M from AUX is a device that extracts energy from the outside and transfers it indoors, providing heating and cooling. It heats the space by extracting heat from the environment and channeling it indoors, while for cooling, it extracts heat from the interior and expels it into the environment.

It can be connected to a single-phase supply, consuming a small percentage of electrical energy, drawing the remaining energy from the environment, resulting in energy and cost savings. The ratio of energy required for the pump's operation corresponds to approximately ¾ from the environment and ¼ from electricity.

The technology used is air-to-water, heating or cooling the water, which is then channeled into the interior of the residence. The system is monoblock, with all construction elements integrated into one outdoor unit. This offers ease of installation and immediate connection to the water system.

It is considered medium temperature, as the water temperature can reach up to 60°C, and it can be combined with underfloor heating or fan coils. The recommendation for the most suitable pump is made by an experienced engineer, who suggests the pump that will offer maximum efficiency at the lowest operating cost.

  • Cooling / Heating Performance
  • Heating (medium zone) Water outlet temperature 35°C: Output (kW) 12.2, Consumption (kW) 2.44, COP 4.96
  • Heating (medium zone) Water outlet temperature 55°C: Output (kW) 12, Consumption (kW) 3.86, COP 3.11
  • Cooling Water outlet temperature 18°C: Output (kW) 12, Consumption (kW) 3, EER 4
  • Cooling Water outlet temperature 7°C: Output (kW) 11.7, Consumption (kW) 4.3, EER 2.75
  • SCOP (medium zone)
  • Water outlet 35°C/55°C: 4.82/3.46
  • Seasonal Energy Class Heating (medium zone)
  • Water outlet 35°C/55°C: A+++ / A++
  • Electrical Specifications
  • Power Supply Internal (V~,Hz,Ph): 380-415/3/50
  • MOP (Maximum Overcurrent Protection Amperes): 14
  • Dimensions & Operation
  • Piping Dimensions: G1"BSP
  • Expansion Tank: 8lt
  • Refrigerant: R32 / 1.70 Kg
  • Noise Level / Sound Power: 31 / 62 dB(A)
  • Weight
  • Net/Gross: 141 / 153 kg
  • Unit Dimensions
  • Unit: 1385x520x933 mm
  • Packing: 1465x550x1095 mm
  • Temperature Setting Range
  • Cooling: 5 - 25°C
  • Heating: 12 - 65°C
  • Operating Range of External Temperature
  • Cooling: -5 - 43°C
  • Heating: -25 - 35°C

Manufacturer

See full description

Specifications

Specifications

Product Number
ACHP-H12/5R3HA-R32

Technical Specifications

Rated Thermal Power (7ºC - 35ºC)
12 kW
Maximum Water Temperature
60 °C
Heating Type
Air to Water
System Type
Monoblock
Cooling
Yes
Domestic Hot Water
with Domestic Water Supply
Power Source
Three-Phase
Type of Refrigerant Fluid
R32

Energy Class

Energy Class (35ºC)
A+++
Energy Class (55ºC)
A++
COP (7ºC - 35ºC)
4.96
EER (7ºC - 35ºC)
4
Outdoor Unit Noise Level
63 dB

Outdoor Dimensions

Length
1385 mm
Height
1095 mm
Length
520 mm

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description & Specifications

The heat pump ACHP-H12/5R3HA-M from AUX is a device that extracts energy from the outside and transfers it indoors, providing heating and cooling. It heats the space by extracting heat from the environment and channeling it indoors, while for cooling, it extracts heat from the interior and expels it into the environment.

It can be connected to a single-phase supply, consuming a small percentage of electrical energy, drawing the remaining energy from the environment, resulting in energy and cost savings. The ratio of energy required for the pump's operation corresponds to approximately ¾ from the environment and ¼ from electricity.

The technology used is air-to-water, heating or cooling the water, which is then channeled into the interior of the residence. The system is monoblock, with all construction elements integrated into one outdoor unit. This offers ease of installation and immediate connection to the water system.

It is considered medium temperature, as the water temperature can reach up to 60°C, and it can be combined with underfloor heating or fan coils. The recommendation for the most suitable pump is made by an experienced engineer, who suggests the pump that will offer maximum efficiency at the lowest operating cost.

  • Cooling / Heating Performance
  • Heating (medium zone) Water outlet temperature 35°C: Output (kW) 12.2, Consumption (kW) 2.44, COP 4.96
  • Heating (medium zone) Water outlet temperature 55°C: Output (kW) 12, Consumption (kW) 3.86, COP 3.11
  • Cooling Water outlet temperature 18°C: Output (kW) 12, Consumption (kW) 3, EER 4
  • Cooling Water outlet temperature 7°C: Output (kW) 11.7, Consumption (kW) 4.3, EER 2.75
  • SCOP (medium zone)
  • Water outlet 35°C/55°C: 4.82/3.46
  • Seasonal Energy Class Heating (medium zone)
  • Water outlet 35°C/55°C: A+++ / A++
  • Electrical Specifications
  • Power Supply Internal (V~,Hz,Ph): 380-415/3/50
  • MOP (Maximum Overcurrent Protection Amperes): 14
  • Dimensions & Operation
  • Piping Dimensions: G1"BSP
  • Expansion Tank: 8lt
  • Refrigerant: R32 / 1.70 Kg
  • Noise Level / Sound Power: 31 / 62 dB(A)
  • Weight
  • Net/Gross: 141 / 153 kg
  • Unit Dimensions
  • Unit: 1385x520x933 mm
  • Packing: 1465x550x1095 mm
  • Temperature Setting Range
  • Cooling: 5 - 25°C
  • Heating: 12 - 65°C
  • Operating Range of External Temperature
  • Cooling: -5 - 43°C
  • Heating: -25 - 35°C

Manufacturer

Product Number
ACHP-H12/5R3HA-R32

Technical Specifications

Rated Thermal Power (7ºC - 35ºC)
12 kW
Maximum Water Temperature
60 °C
Heating Type
Air to Water
System Type
Monoblock
Cooling
Yes
Domestic Hot Water
with Domestic Water Supply
Power Source
Three-Phase
Type of Refrigerant Fluid
R32

Energy Class

Energy Class (35ºC)
A+++
Energy Class (55ºC)
A++
COP (7ºC - 35ºC)
4.96
EER (7ºC - 35ºC)
4
Outdoor Unit Noise Level
63 dB

Outdoor Dimensions

Length
1385 mm
Height
1095 mm
Length
520 mm

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

6.200,00 €