Voltage Testers

Voltage Tester AC with Measurement Range 70 - 250V

The voltage detector combines the advantages of a traditional phase detector and a non-contact voltage detector. The traditional phase detector allows quick and easy confirmation of the live wire. It...

The voltage detector combines the advantages of a traditional phase detector and a non-contact voltage detector. The traditional phase detector allows quick and easy confirmation of the live wire. It is suitable for voltage detection between 70 - 250 V AC with contact. If the LED lights up, the wire is live. If the LED does not light up, the voltage of the...

See full description See full description
9 73
10 Coins 10 Coins
Delivery Wed, 01 Jul - Fri, 03 Jul
2,50 € to a Skroutz Point
or   3,50 €   shipping cost
Sent from Romania
From Mercaton Store
Romania
20+ pieces
See Voltage / Cable Testers on the page of Mercaton Store
What if it breaks?

You have at least a 2-year warranty. Contact us by phone and we will immediately take care of the repair, replacement or refund of your money, completely free of charge.

What if I change my mind?

No problem, as long as it's within 14 days. We'll come pick it up or you can choose the Skroutz Point that suits you, completely free for up to 2 times per year, and we'll refund your money. Get Skroutz Plus to enjoy unlimited free returns.

Description

Description

The voltage detector combines the advantages of a traditional phase detector and a non-contact voltage detector. The traditional phase detector allows quick and easy confirmation of the live wire. It is suitable for voltage detection between 70 - 250 V AC with contact. If the LED lights up, the wire is live. If the LED does not light up, the voltage of the tested wire is below 70 V AC. In non-contact mode, the detector can detect voltages between 70 - 600 V AC, minimizing the risk of electric shock and offering safer phase confirmation.

  • Polarity test
  • Continuity test
  • Safe non-contact detection
  • Light point

Warning!

  • The detector must not be used for measuring voltages above the specified nominal values.
  • Proper indication is guaranteed only between -10 and +50 °C and in the frequency range of 50-500 Hz.
  • The visibility of the signal may be affected by adverse lighting conditions (e.g., direct sunlight).
  • Before use, check the proper operation of the detector (AUTO-TEST).
  • Do not use the detector in the presence of moisture (including dew, condensation, or rain).
  • The blade of the phase detector should only be used for voltage confirmation. Any other actions should be performed only with the voltage disconnected! Do not use the detector if it is damaged!

Note that under certain conditions, static electricity can accumulate on the plastic housing, causing false indications. Never attempt to modify the internal components of the detector.

Technical specifications:

  • Operating temperature: -10 °C - +50 °C
  • Voltage detection with contact: 70 V - 250 V AC
  • Voltage detection without contact: 70 V - 600 V AC
  • Frequency: 50/60 Hz
  • Polarity test: 3 - 36 V DC
  • Continuity test: 0 - 50 mA
  • Power supply: Batteries 392A, AG3, LR41, 192 (2 x 1.5V included)
  • Dimensions: 138 x 18 mm

Manufacturer

See full description

Specifications

Specifications

Type of Current
AC
Min Voltage
70 V
Max Voltage
250 V
NCV
Yes
with Buzzer
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications
Questions

Questions

Do you have a question about the product?

Those users who have this product can help you

Ask for the product

Description & Specifications

The voltage detector combines the advantages of a traditional phase detector and a non-contact voltage detector. The traditional phase detector allows quick and easy confirmation of the live wire. It is suitable for voltage detection between 70 - 250 V AC with contact. If the LED lights up, the wire is live. If the LED does not light up, the voltage of the tested wire is below 70 V AC. In non-contact mode, the detector can detect voltages between 70 - 600 V AC, minimizing the risk of electric shock and offering safer phase confirmation.

  • Polarity test
  • Continuity test
  • Safe non-contact detection
  • Light point

Warning!

  • The detector must not be used for measuring voltages above the specified nominal values.
  • Proper indication is guaranteed only between -10 and +50 °C and in the frequency range of 50-500 Hz.
  • The visibility of the signal may be affected by adverse lighting conditions (e.g., direct sunlight).
  • Before use, check the proper operation of the detector (AUTO-TEST).
  • Do not use the detector in the presence of moisture (including dew, condensation, or rain).
  • The blade of the phase detector should only be used for voltage confirmation. Any other actions should be performed only with the voltage disconnected! Do not use the detector if it is damaged!

Note that under certain conditions, static electricity can accumulate on the plastic housing, causing false indications. Never attempt to modify the internal components of the detector.

Technical specifications:

  • Operating temperature: -10 °C - +50 °C
  • Voltage detection with contact: 70 V - 250 V AC
  • Voltage detection without contact: 70 V - 600 V AC
  • Frequency: 50/60 Hz
  • Polarity test: 3 - 36 V DC
  • Continuity test: 0 - 50 mA
  • Power supply: Batteries 392A, AG3, LR41, 192 (2 x 1.5V included)
  • Dimensions: 138 x 18 mm

Manufacturer

Type of Current
AC
Min Voltage
70 V
Max Voltage
250 V
NCV
Yes
with Buzzer
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

9,73 €
2,50 € to a Skroutz Point
or   3,50 €   shipping cost